Distance-settable Photoelectric Sensor
E3AS-L Series
Background suppression sensor for
enhanced detection low-reflectivity
objects
• Equipped with Omron's proprietary light emitting element for
stable detection of low-reflective workpieces
• Teaching method allows anyone to set optimal threshold values
• Manufactured using Omron's proprietary laser sealing method
(IP67/IP69K/IP67G *)
• Antifouling coating prevents contamination on the sensing
surface
• IO-Link reduced time required for startups and changeovers
* Only for sensor units.
Refer to Safety Precautions on page 8.
For the most recent information on models that have been certified for
safety standards, refer to your Omron website.
Ordering Information
Sensors [Refer to Dimensions on page 9.]
Connection
method
Sensing distance
(white paper)
Red light
Model
Output
IO-Link baud rate
NPN output
PNP output
PNP output
---
COM2 (38.4 kbps)
COM3 (230.4 kbps)
E3AS-L200MN 2M
E3AS-L200MD 2M
E3AS-L200MT 2M
M8 Connector
E3AS-L200MN M3
E3AS-L200MD M3
E3AS-L200MT M3
M8 Pre-wired
Connector
E3AS-L200MN-M3J 0.3M
E3AS-L200MD-M3J 0.3M
E3AS-L200MT-M3J 0.3M
M12 Pre-wired
Connector 2
E3AS-L200MN-M1TJ 0.3M
E3AS-L200MD-M1TJ 0.3M
E3AS-L200MT-M1TJ 0.3M
E3AS-L80MN 2M
E3AS-L80MD 2M
E3AS-L80MT 2M
M8 Connector
E3AS-L80MN M3
E3AS-L80MD M3
E3AS-L80MT M3
M8 Pre-wired
Connector
E3AS-L80MN-M3J 0.3M
E3AS-L80MD-M3J 0.3M
E3AS-L80MT-M3J 0.3M
M12 Pre-wired
Connector 2
E3AS-L80MN-M1TJ 0.3M
E3AS-L80MD-M1TJ 0.3M
E3AS-L80MT-M1TJ 0.3M
Pre-wired (2 m) 1
10 mm
200 mm
Pre-wired (2 m) 1
10 mm
80 mm
1. Models with 5-m cable length are also available with “5M” suffix. (Example: E3AS-L200MN 5M)
2. The Pre-wired Connector (M12) is Smartclick Connector.
1
E3AS-L Series
Accessories (Sold Separately)
Sensor I/O Connectors (Sockets on One Cable End)
(Models for Connectors / Pre-wired Connectors)
A Sensor I/O Connector is not provided with the Sensor. Order separately as needed.
Round Water-resistant Connectors XS3F-M8 series
Appearance
Cable
specification
Cable diameter
(mm)
No. of
cable cores
(Poles)
Cable
connection
direction
Cable length (m)
Sensor I/O Connector
model number
M8 Connector
Straight type
2
XS3F-M8PVC4S2M
5
XS3F-M8PVC4S5M
2
XS3F-M8PVC4A2M
5
XS3F-M8PVC4A5M
Straight
PVC cable
5 dia.
4
Right-angle type
Right-angle
Note: 1. The XS3W (Socket and Plug on Cable Ends) is also available. Refer to XS3W-M8/XS3F-M8 Series Datasheet (Cat. No. G140).
2. The connectors will not rotate after they are connected.
3. The cable is fixed at an angle of 180° from the sensor emitter/receiver surface.
Round Water-resistant Connectors XS5 series
Appearance
Cable specification
Cable diameter
(mm)
Cable connection
direction
M12 Smartclick Connector
Straight type
Cable length (m)
Sensor I/O Connector
model number
2
XS5F-D421-D80-F
5
XS5F-D421-G80-F
2
XS5F-D422-D80-F
5
XS5F-D422-G80-F
Straight
PVC robot cable
6 dia.
Right-angle type
Right-angle
Note: 1. The XS5W (Socket and Plug on Cable Ends) is also available. Refer to XS5 on your Omron website for details.
2. The connectors will not rotate after they are connected.
3. The cable is fixed at an angle of 180° from the sensor emitter/receiver surface.
2
E3AS-L Series
Mounting Brackets [Refer to Dimensions on page 10.]
A Mounting Bracket is not enclosed with the Sensor. Order separately as needed.
Appearance
L-shaped
Mounting
Bracket
Horizontal
Protective
Cover
Bracket
Rear
Mounting
Bracket
Robust
Mounting
Bracket
L-shaped
Mounting
Bracket
Horizontal
Protective
Cover
Bracket
Robust
Mounting
Bracket
Model
(material)
Applicable Sensor E3AS series
Pre-wired
M8 Pre-wired
Connector
M12 Pre-wired
Smartclick Connector
M8 Connector
E39-L201
(SUS304)
Yes
Yes
Yes
---
E39-L202
(SUS304)
Yes
Yes
Yes
---
E39-L203
(SUS304)
Yes
Yes
Yes
Yes 2
E39-L204
(SUS304)
Yes
Yes
Yes
---
E39-L211
(SUS304)
--- 1
--- 1
--- 1
Yes 3
E39-L212
(SUS304)
--- 1
--- 1
--- 1
Yes 3
E39-L214
(SUS304)
--- 1
--- 1
--- 1
Yes 3
1. Can be used for Pre-wired models, M8 Pre-wired Connector models, and M12 Pre-wired Smartclick Connector models. However, confirm the
bracket shape in advance.
2. Confirm the installation environment and bracket shape of the Sensor I/O Connector to be connected.
3. Use an L-shaped Sensor I/O Connector. Straight types cannot be installed.
3
E3AS-L Series
Ratings and Specifications
Sensing method
Model
Item
Distance-settable
NPN output
E3AS-L200MN
E3AS-L80MN
PNP output/ COM2
E3AS-L200MD
E3AS-L80MD
PNP output/ COM3
E3AS-L200MT
E3AS-L80MT
Sensing distance
10 mm to the set distance (White paper or black paper 100 × 100 mm)
Setting range
40 to 200 mm
(White paper or black paper 100 × 100 mm)
20 to 80 mm
(White paper or black paper 100 × 100 mm)
Spot diameter (reference value)
25 × 25 mm at distance of 200 mm
4 mm dia. (at distance of 80 mm)
Differential travel
10% max. of set distance
White paper: 2% max. of set distance
Black paper: 5% max. of set distance
Reflectivity characteristic
(black/white error)
10% max. of set distance
5% max. of set distance
Light source (wavelength)
Red LED (624 nm)
Red LED (650 nm)
Power supply voltage
10 to 30 VDC (including 10% ripple (p-p)), Class2
Current consumption
35 mA max.
Control output
Input/output
Load power supply voltage: 30 VDC max., Class2, Load current: 100 mA max.
(Residual voltage: Load current of less than 10 mA: 1 V max. Load current of 10 to 100 mA: 2 V max.)
Open-collector output (NPN/PNP output depending on model)
NPN
OUTPUT 1: NO (Normally open), OUTPUT 2: NC (Normally closed)
PNP/COM2
PNP/COM3
OUTPUT 1: NO (Normally open)/COM
□, OUTPUT 2: NC (Normally closed)
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time
Operate or reset: 1 ms max.
Distance setting
Teaching method/IO-Link communications
Ambient illumination (Receiver side)
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Ambient temperature range
Operating: -25 to 55°C, Storage: -40 to 70°C (with no icing or condensation)
Ambient humidity range
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance
20 M min. at 500 VDC
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IP67 (IEC60529) and IP67G 1 (JIS C 0920 Annex 1), IP69K (ISO20653)
Indicators
Operation indicator (orange), Stability & Communication indicator (green 2)
Connection method
Pre-wired (standard cable length: 2 m), M8 Connector, M8 Pre-wired Connector (standard cable length: 0.3m),
M12 Pre-wired Smartclick Connector (standard cable length: 0.3m)
Weight
(packed state/
Sensor only)
Materials
Pre-wired (2 m)
Approx. 135 g/approx. 90 g
M8 Connector
Approx. 75 g/approx. 30 g
M8 Pre-wired Connector
(0.3 m)
Approx. 85 g/approx. 40 g
M12 Pre-wired
Approx. 95 g/approx. 50 g
Smartclick Connector (0.3m)
Case
Stainless steel (SUS316L)
Lens
Methacrylate resin (PMMA)
Display
Polyamide 11 (PA11)
Main IO-Link functions
IO-Link specification
IO-Link
Baud rate
Communication
Data length
specifications
Minimum cycle time
Accessories
Operation mode switching between NO and NC, execution of teaching (2-point teaching, Background teaching),
setup of the threshold, timer function of the control output and timer time selecting, Restore Factory Settings, Key
Lock (Unlock, Lock, Lock (No Button))
Ver. 1.1
COM2 (38.4 kbps), COM3 (230.4 kbps)
PD size: 1 byte, OD size: 1 byte (M-sequence type: TYPE_2_1)
COM2: 3.5 ms, COM3: 1.2 ms
Instruction manual, compliance sheet and index list (attached for IO-Link type only),
Note: Mounting Brackets must be ordered separately.
1. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.
2. IO-Link Communication mode: blinking
4
E3AS-L Series
Engineering Data (Reference Value)
15
Set distance: 200 mm
Sensing object: White paper,
100 x 100 mm
Y
10
E3AS-L80
Operating Range Y (mm)
Operating Range Y (mm)
Operating Range
E3AS-L200
X
5
0
2
1.5
1
0.5
Y
X
0
Set distance: 80 mm
Sensing object: White paper,
100 x 100 mm
-0.5
-5
-1
-10
-15
-1.5
0
50
100
150
200
-2
0
250
10
20
30
40
50
35
30
25
20
70
80
90
E3AS-L80
Spot diameter (mm)
Spot diameter (mm)
Spot Diameter vs. Sensing Distance
E3AS-L200
60
Distance X (mm)
Distance X (mm)
6
5
4
3
15
2
10
1
5
0
50
100
150
200
250
300
350
0
20
40
60
80
Distance X (mm)
200
180
182
mm
182
mm
160
140
120
80
40
Set distance: 80 mm
70
70
mm
71
mm
60
50
30
Set distance: 40 mm
35 mm
Set distance: 20 mm
20
35 mm
15.5 mm
15.5 mm
10
20
0
80
40
100
60
120
E3AS-L80
Set distance: 200 mm
Sensing distance (mm)
Sensing distance (mm)
Close-range Characteristics
E3AS-L200
100
Distance X (mm)
2 mm
0 mm
0 mm
1 mm
0
White paper Black paper White paper Black paper
1.5 mm 4 mm
1 mm
4 mm
White paper Black paper White paper Black paper
Material
Material
10
Differential distance (%)
Differential distance (%)
Differential distance for each sensing object Vs. Distance
E3AS-L200
E3AS-L80
Reflectance of sensing object/ Reflectance of background
1. 10% (Black paper)/ 90% (White paper)
2. 18% (Gray paper)/ 90% (White paper)
3. 90% (White paper)/ 90% (White paper)
8
6
2
5
Reflectance of sensing object/ Reflectance of background
1. 10% (Black paper)/ 90% (White paper)
2. 18% (Gray paper)/ 90% (White paper)
3. 90% (White paper)/ 90% (White paper)
4
3
2
1
2
4
3
1
2
1
3
0
50
100
150
200
250
Set distance (mm)
0
20
40
60
80
100
Set distance (mm)
5
E3AS-L Series
Sensing Object Angle Characteristics
Horizontal
5
Set distance: 200 mm
Sensing object: White paper/
Black paper 100×100 mm
White paper
0
-5
Black paper
-10
Vertical
Inclination
Change in sensing distance (%)
Change in sensing distance (%)
E3AS-L200
Vertical
5
Set distance: 200 mm
Sensing object: White paper/
Black paper 100×100 mm
White paper
0
-5
Black paper
Horizontal
Inclination
-10
Angle
Angle
-15
+θ
-15
+θ
-θ
-θ
Sensing object
Center line
Sensing object
Center line
-20
-50
-40
-30
-20
-10
0
10
20
30
-20
-50
40 50
-40
-30
-20
-10
0
10
20
Angle θ (°)
Horizontal
10
5
Set distance: 80 mm
Sensing object: White paper/
Black paper 100×100 mm
White paper
Black paper
0
-5
Vertical
Inclination
-10
5
Set distance: 80 mm
Sensing object: White paper/
Black paper 100×100 mm
White paper
0
Black paper
-5
Horizontal
Inclination
-10
Angle
Angle
-θ
-θ
Sensing object
Center line
Sensing object
Center line
-40
-30
-20
-10
+θ
-15
+θ
-15
-20
-50
40 50
Angle θ (°)
Change in sensing distance (%)
Change in sensing distance (%)
E3AS-L80
Vertical
30
0
10
20
30
-20
-50
40 50
-40
-30
-20
-10
0
10
20
30
40 50
Angle θ (°)
Angle θ (°)
Sensing Distance vs. Sensing Object Material
Sensing distance (mm)
Sensing distance (mm)
E3AS-L200
E3AS-L80
(Set Distance of 200 mm using White Paper) (Set Distance of 80 mm using White Paper)
200
180
160
140
120
80
70
60
50
40
100
80
30
60
20
40
10
20
Mirror
SUS
Black rubber
Black paper
Cardboard
Veneer
Mirror
SUS
Black rubber
Black paper
Cardboard
Veneer
White paper
6
Material
White paper
0
0
Material
E3AS-L Series
I/O Circuit Diagrams/ Timing Charts
NPN Output
Model
Timing chart
Output circuit
Brown
+V
OUT1
OUT2
Threshold
Stable NEAR
E3AS-L□N
Stability&Communication
indicator (green) 1
ON
OFF
Operation indicator (orange)
ON
OFF
Control output 1
ON
OFF
Control output 2 2
ON
OFF
0V
Stable FAR
Black
Load 100mA Load 100mA
max.
max.
White
10 to 30 VDC
Blue
Connector Pin Arrangement
M12 Pre-wired
Smartclick Connector
M8 Connector,
M8 Pre-wired Connector
1. Turns off when there is insufficient margin for incident light. In that case, place the workpiece closer to ensure sufficient receiving light intensity.
2. The initial value of control output 2 is reverse of control output 1.
PNP Output
Model
Output circuit
IO-Link Communication mode (COM mode) 2
Standard I/O mode (SIO mode) 1
+V
OUT1
OUT2
0V
E3AS-L□D
E3AS-L□T
Brown
+V
10 to 30 VDC
Black
C/Q
White
Load
Blue
100mA
max.
Load
DO
100mA
max.
0V
Connector Pin Arrangement
M12 Pre-wired
Smartclick Connector
Brown
+V
Black
C/Q
White
IO-Link Master Unit
DI/DO
Blue
0V
Connector Pin Arrangement
M8 Connector,
M8 Pre-wired Connector
M12 Pre-wired
Smartclick Connector
M8 Connector,
M8 Pre-wired Connector
1. Standard I/O mode is used as PNP ON/OFF output.
2. IO-Link Communication mode is used for communications with the IO-Link Master. C/Q performs IO-Link communications. Sensor output DO
performs ON/OFF output.
Timing charts
Output mode
Threshold
Stable NEAR
Stability&Communication
indicator (green) 1
Standard I/O mode
(SIO mode)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Operation indicator (orange)
Control output 1 3
Control output 2 2
IO-Link
Communication
mode (COM mode)
Stability&
Communication
indicator (green)
Control output 2 2
ON delay
Sensing
object
Flashing
(1 second cycle)
Operation indicator (orange)
Communication output
Stable FAR
1. Turns off when there is insufficient margin for incident light. In
that case, place the workpiece closer to ensure sufficient
receiving light intensity.
2. The initial value of control output 2 is reverse of control output 1.
3. The timer function of the control output 2 can be set up by the
IO-Link communications. (It is able to select ON delay, OFF
delay, or one-shot function and select a timer time of 1 to 9,999
ms (T).)
ON
OFF
1
0
ON
OFF
Present
Not
present
ON
OFF
ON
NC
OFF
NO
1
0
1
0
OFF delay
Sensing
object
T
ON
OFF
ON
NC
OFF
NO
T
1
0
1
0
One Shot
Sensing
object
Present
Not
present
T
ON
OFF
ON
NC
OFF
NO
T
Present
Not
present
1
0
1
0
T
T
Please contact your Omron sales representative regarding the IOLink setup file (IODD file).
Note: Shown above are the factory settings. Refer to the index list for the default settings at time of shipment from factory.
PNP/COM output logic can be reversed by IO-Link communication.
The operation indicator (orange) lights up when control output 1 is ON or communication output is 1.
Nomenclature
E3AS-L200
E3AS-L80
Operation indicator (orange)
Stability&Communication
indicator (green)
Teach button
Note: The indicators work differently depending on sensor status.
7
E3AS-L Series
Safety Precautions
Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.
Warning Indications
Warning level
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
moderate injury, or may result in serious
injury or death. Additionally there may be
significant property damage.
WARNING
Caution level
Indicates a potentially hazardous situation
which, if not avoided, may result in minor
or moderate injury or in property damage.
CAUTION
Precautions for
Safe Use
Supplementary comments on what to do
or avoid doing, to use the product safely.
Precautions for
Correct Use
Supplementary comments on what to do
or avoid doing, to prevent failure to
operate, malfunction or undesirable effect
on product performance.
Meaning of Product Safety Symbols
General prohibition
Indicates the instructions of unspecified
prohibited action
Caution, fire
Indicates the possibility of fires under specific
conditions
General Caution
Indicates unspecified general alert
Caution, explosion
Indicates the possibility of explosion under
specific conditions
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purpose.
Do not use the product with voltage in excess of the
rated voltage.
Excess voltage may result in malfunction or fire.
CAUTION
Its component may be damaged and/or degree of
protection may be degraded.
Please do not apply high pressure water intensively
at one place during cleaning.
Never use the product with an AC power supply.
Otherwise, explosion may result.
8
Precautions for Safe Use
The following precautions must be observed to ensure safe operation.
(1) Do not reverse the power supply connection or connect to an AC
current.
(2) Do not short the load.
(3) Be sure that before making supply the supply voltage is less than
the maximum rated supply voltage (30 VDC).
(4) Do not use the product in environments subject to flammable or
explosive gases.
(5) Do not use the product under a chemical or an oil environment
without prior evaluation.
(6) Do not attempt to modify the product.
Precautions for Correct Use
(1) Do not hit the product using a hammer for installation.
(2) The product must be installed with the specified torque or less.
For M8 connector, the proper tightening torque is from 0.3 to 0.4
Nm. For M12 connector, the proper tightening torque is from
0.39 to 0.49 Nm. In case of M12 smartclick connector, manually
tighten the connector.
(3) Do not use the product in any atmosphere or environment that
exceeds the ratings.
(4) Output pulses may occur when the power supply is turned OFF.
We recommend that you turn OFF the power supply to the load
or load line first.
(5) Use an extension cable less than 100 m long for Standard I/O
mode and less than 20 m for IO-Link Communication mode.
(6) Do not pull on the cable with excessive strength.
(7) Please wait for at least 100 ms after turning on the product's
power until it is available for use.
(8) Though this is type IP67, do not use in the water, rain or outdoors.
(9) If the Sensor wiring is placed in the same conduits or ducts as
high-voltage or high-power lines, inductive noise may cause
malfunction or damage. Wire the cables separately or use a
shielded cable.
(10) Do not use the product in locations subject to direct sunlight.
(11) Do not use the product where humidity is high and dew
condensation may occur.
(12) Do not use the product where corrosive gases may exist.
(13) If high-pressure washing water and so on hits the teach button, it
might lead to malfunctioning. So, consider use of the key lock
function.
(14) Do not apply high-pressure washing water directly to the sensor's
light emitting / receiving surface from a short distance. As the
antifouling feature may be impaired, keep a sufficient distance
from the light emitting / receiving surface.
(15) Do not use the product at a location subject to shock or vibration.
(16) To use a commercially available switching regulator, FG (frame
ground) must be grounded.
(17) Do not use organic solvents (e.g. paint thinner and alcohol) for
cleaning. Otherwise optical properties and protective structure
may deteriorate.
(18) Be sure to check the influence caused by surrounding
environments such as background objects and LED lighting
before using the product.
(19)
Please dispose in accordance with applicable regulations.
E3AS-L Series
Dimensions
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
Pre-wired Models/Pre-wired Connector Models
E3AS-L200□ (-M1TJ/-M3J)
E3AS-L80□ (-M1TJ/-M3J)
M12 Pre-wired Smartclick Connector type
E3AS-L200 -M1TJ/E3AS-L80 -M1TJ
□
14
□
7.6
4.25 dia. vinyl-insulated
round cable with 4 conductors.
2
Operation indicator (orange)
Stability&Communication indicator (green)
M12×P1
Teach button
□
4.6
Receiver
lens
(12.1)
9.8
39.3
3
4
M8 Pre-wired connector type
E3AS-L200 -M3J/E3AS-L80 -M3J
3
1.5
37.9
23.4
22
Two, M3
11.4
1
□
4.25 dia. vinyl-insulated
round cable with 4 conductors.
2
4
25.4
M8×P1
1
3
Emitter
lens
7.9
Minimum bending radius/unbendable
length of cord
4.25 dia. vinyl-insulated round cable
with 4 conductors (Conductor cross
section: 0.2 mm2 (AWG24), Insulator
diameter: 1.1 mm), Standard length: 2 m
5.1
Unbendable length
5 mm
Minimum bending radius
R13 mm
Connector Models
E3AS-L200□ M3
E3AS-L80□ M3
14
7.6
Operation indicator (orange)
Stability&Communication indicator (green)
Teach button
22
Two, M3
11.4
1.5
(12.1)
37.9
Receiver
lens
9.8
3
4.6
25.4
Emitter
lens
7.9
M8×P1
5.1
9.6
9
E3AS-L Series
Accessories (Sold Separately)
Mounting Brackets
E39-L201
Photoelectric Sensor
Accessory are installed
(Example of E3AS-L200 )
3
22
□
11.4
(Four, R1.8)
22.4
16
4
3.5
3.5
6.8
8.5
9
31
8.3
*
14.5
Emitting center
48
17.4
25.4
41.4
R25.4
24.1
16
8.1
16
T3
27
Material: Stainless steel (SUS304)
* Accessories
2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W)
E39-L202
Photoelectric Sensor
Accessory are installed
(Example of E3AS-L200 )
□
11.9
15
5.9
26.7
16.9
13.3
6.7
Four, 3.5 dia.
7
*
Emitting center
46
45°
45°
17.4
25.4
25.4
9.4
76
8.1
45°
45°
38.4
30.3
33
33
18
T3
18
14°
(Two, R1.8)
8.5
3.5
7
3.5
15.7
R12
18.7
Material: Stainless steel (SUS304)
* Accessories
2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W)
E39-L203
Photoelectric Sensor
Accessory are installed
(Example of E3AS-L200 )
□
22
T3
13.5
3.5 dia.
6.7
6
Emitting center
31.9
3.5
(Two, R1.8)
Two, 3.5
20°
44
Material: Stainless steel (SUS304)
* Accessories
2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W)
10
32.9
17.4
R25.4
6
(Four, R1.8)
19.85
6.4
*
7
28.6
42
38.2
32.8
8.1
R25.4
E3AS-L Series
E39-L204
Photoelectric Sensor
Accessory are installed
(Example of E3AS-L200 )
50°
2-3.5
□
(Four, R1.8)
55 dia.
41.5 dia.
14.3
28.5
(28.5)
22.1
12.7
6
6.4
*
1
6.6
21.9
50.2
Two, 3.5
Two, R25.4
45.2
17.4
8.1
Emitting center
23.8
15.7
R25.4
T3
Two, 5 dia.
Material: Stainless steel (SUS304)
* Accessories
2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W)
E39-L211
Photoelectric Sensor
Accessory are installed
(Example of E3AS-L200 )
3
□
(Four, R1.8)
11.4
22.4
16
4
22
3.5
3.5
6.8
8.3
8.5
9
31
14.5
6.4
*
Emitting center
17.4
25.4
8.1
69.7
R25.4
37.5
45.6
37.5
T3
27
Material: Stainless steel (SUS304)
* Accessories
2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W)
11
E3AS-L Series
E39-L212
Photoelectric Sensor
Accessory are installed
(Example of E3AS-L200 )
□
11.9
5.9
15
26.7
13.9
13.3
6.7
7
*
Four, 3.5 dia
Emitting center
17.4
25.4
10.3
25.4
8.1
71.6
97.6
60
52
8.5
T3
(Two, R1.8)
3.5
3.5
7
R12
16.6
19.6
Material: Stainless steel (SUS304)
* Accessories
2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W)
E39-L214
Photoelectric Sensor
Accessory are installed
(Example of E3AS-L200 )
50°
2-3.5
□
(Four, R1.8)
55 dia.
41.5 dia.
14.2
28.5
22.1
12.7
6
6.4
6.6
Two, R25.4
*
1
(Four, R1.8)
21.9
17.4
Two, 3.5
8.1
72.6
67.6
9
38.4
45°
30.4
16.7
T3
Two, 5°
Material: Stainless steel (SUS304)
* Accessories
2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W)
12
38.6
Emitting center
R25.4
46.5
OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com
OMRON ARGENTINA • SALES OFFICE
Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483
mela@omron.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron.
com
OTHER OMRON LATIN AMERICA SALES
+54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com
Controllers & I/O
• Machine Automation Controllers (MAC) • Motion Controllers
• Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O
Authorized Distributor:
Robotics
• Industrial Robots • Mobile Robots
Operator Interfaces
• Human Machine Interface (HMI)
Motion & Drives
• Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems
• Frequency Inverters
Vision, Measurement & Identification
• Vision Sensors & Systems • Measurement Sensors • Auto Identification
Systems
Sensing
• Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors
• Rotary Encoders • Ultrasonic Sensors
Safety
• Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems
• Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices
• Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays
Control Components
• Power Supplies • Timers • Counters • Programmable Relays
• Digital Panel Meters • Monitoring Products
Switches & Relays
• Limit Switches • Pushbutton Switches • Electromechanical Relays
• Solid State Relays
Software
• Programming & Configuration • Runtime
E588BI-E3-02
Note: Specifications are subject to change.
© 2019 Omron. All Rights Reserved.
Printed on recycled paper.
Printed in U.S.A.