0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
E3AS-L200MN 2M

E3AS-L200MN 2M

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    PHOTOELECTRIC SENSOR; BACKGROUND

  • 数据手册
  • 价格&库存
E3AS-L200MN 2M 数据手册
Distance-settable Photoelectric Sensor E3AS-L Series Background suppression sensor for enhanced detection low-reflectivity objects • Equipped with Omron's proprietary light emitting element for stable detection of low-reflective workpieces • Teaching method allows anyone to set optimal threshold values • Manufactured using Omron's proprietary laser sealing method (IP67/IP69K/IP67G *) • Antifouling coating prevents contamination on the sensing surface • IO-Link reduced time required for startups and changeovers * Only for sensor units. Refer to Safety Precautions on page 8. For the most recent information on models that have been certified for safety standards, refer to your Omron website. Ordering Information Sensors [Refer to Dimensions on page 9.] Connection method Sensing distance (white paper) Red light Model Output IO-Link baud rate NPN output PNP output PNP output --- COM2 (38.4 kbps) COM3 (230.4 kbps) E3AS-L200MN 2M E3AS-L200MD 2M E3AS-L200MT 2M M8 Connector E3AS-L200MN M3 E3AS-L200MD M3 E3AS-L200MT M3 M8 Pre-wired Connector E3AS-L200MN-M3J 0.3M E3AS-L200MD-M3J 0.3M E3AS-L200MT-M3J 0.3M M12 Pre-wired Connector 2 E3AS-L200MN-M1TJ 0.3M E3AS-L200MD-M1TJ 0.3M E3AS-L200MT-M1TJ 0.3M E3AS-L80MN 2M E3AS-L80MD 2M E3AS-L80MT 2M M8 Connector E3AS-L80MN M3 E3AS-L80MD M3 E3AS-L80MT M3 M8 Pre-wired Connector E3AS-L80MN-M3J 0.3M E3AS-L80MD-M3J 0.3M E3AS-L80MT-M3J 0.3M M12 Pre-wired Connector 2 E3AS-L80MN-M1TJ 0.3M E3AS-L80MD-M1TJ 0.3M E3AS-L80MT-M1TJ 0.3M Pre-wired (2 m) 1 10 mm 200 mm Pre-wired (2 m) 1 10 mm 80 mm 1. Models with 5-m cable length are also available with “5M” suffix. (Example: E3AS-L200MN 5M) 2. The Pre-wired Connector (M12) is Smartclick Connector. 1 E3AS-L Series Accessories (Sold Separately) Sensor I/O Connectors (Sockets on One Cable End) (Models for Connectors / Pre-wired Connectors) A Sensor I/O Connector is not provided with the Sensor. Order separately as needed. Round Water-resistant Connectors XS3F-M8 series Appearance Cable specification Cable diameter (mm) No. of cable cores (Poles) Cable connection direction Cable length (m) Sensor I/O Connector model number M8 Connector Straight type 2 XS3F-M8PVC4S2M 5 XS3F-M8PVC4S5M 2 XS3F-M8PVC4A2M 5 XS3F-M8PVC4A5M Straight PVC cable 5 dia. 4 Right-angle type Right-angle Note: 1. The XS3W (Socket and Plug on Cable Ends) is also available. Refer to XS3W-M8/XS3F-M8 Series Datasheet (Cat. No. G140). 2. The connectors will not rotate after they are connected. 3. The cable is fixed at an angle of 180° from the sensor emitter/receiver surface. Round Water-resistant Connectors XS5 series Appearance Cable specification Cable diameter (mm) Cable connection direction M12 Smartclick Connector Straight type Cable length (m) Sensor I/O Connector model number 2 XS5F-D421-D80-F 5 XS5F-D421-G80-F 2 XS5F-D422-D80-F 5 XS5F-D422-G80-F Straight PVC robot cable 6 dia. Right-angle type Right-angle Note: 1. The XS5W (Socket and Plug on Cable Ends) is also available. Refer to XS5 on your Omron website for details. 2. The connectors will not rotate after they are connected. 3. The cable is fixed at an angle of 180° from the sensor emitter/receiver surface. 2 E3AS-L Series Mounting Brackets [Refer to Dimensions on page 10.] A Mounting Bracket is not enclosed with the Sensor. Order separately as needed. Appearance L-shaped Mounting Bracket Horizontal Protective Cover Bracket Rear Mounting Bracket Robust Mounting Bracket L-shaped Mounting Bracket Horizontal Protective Cover Bracket Robust Mounting Bracket Model (material) Applicable Sensor E3AS series Pre-wired M8 Pre-wired Connector M12 Pre-wired Smartclick Connector M8 Connector E39-L201 (SUS304) Yes Yes Yes --- E39-L202 (SUS304) Yes Yes Yes --- E39-L203 (SUS304) Yes Yes Yes Yes 2 E39-L204 (SUS304) Yes Yes Yes --- E39-L211 (SUS304) --- 1 --- 1 --- 1 Yes 3 E39-L212 (SUS304) --- 1 --- 1 --- 1 Yes 3 E39-L214 (SUS304) --- 1 --- 1 --- 1 Yes 3 1. Can be used for Pre-wired models, M8 Pre-wired Connector models, and M12 Pre-wired Smartclick Connector models. However, confirm the bracket shape in advance. 2. Confirm the installation environment and bracket shape of the Sensor I/O Connector to be connected. 3. Use an L-shaped Sensor I/O Connector. Straight types cannot be installed. 3 E3AS-L Series Ratings and Specifications Sensing method Model Item Distance-settable NPN output E3AS-L200MN E3AS-L80MN PNP output/ COM2 E3AS-L200MD E3AS-L80MD PNP output/ COM3 E3AS-L200MT E3AS-L80MT Sensing distance 10 mm to the set distance (White paper or black paper 100 × 100 mm) Setting range 40 to 200 mm (White paper or black paper 100 × 100 mm) 20 to 80 mm (White paper or black paper 100 × 100 mm) Spot diameter (reference value) 25 × 25 mm at distance of 200 mm 4 mm dia. (at distance of 80 mm) Differential travel 10% max. of set distance White paper: 2% max. of set distance Black paper: 5% max. of set distance Reflectivity characteristic (black/white error) 10% max. of set distance 5% max. of set distance Light source (wavelength) Red LED (624 nm) Red LED (650 nm) Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class2 Current consumption 35 mA max. Control output Input/output Load power supply voltage: 30 VDC max., Class2, Load current: 100 mA max. (Residual voltage: Load current of less than 10 mA: 1 V max. Load current of 10 to 100 mA: 2 V max.) Open-collector output (NPN/PNP output depending on model) NPN OUTPUT 1: NO (Normally open), OUTPUT 2: NC (Normally closed) PNP/COM2 PNP/COM3 OUTPUT 1: NO (Normally open)/COM □, OUTPUT 2: NC (Normally closed) Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection Response time Operate or reset: 1 ms max. Distance setting Teaching method/IO-Link communications Ambient illumination (Receiver side) Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. Ambient temperature range Operating: -25 to 55°C, Storage: -40 to 70°C (with no icing or condensation) Ambient humidity range Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) Insulation resistance 20 M min. at 500 VDC Dielectric strength 1,000 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance 500 m/s2 for 3 times each in X, Y, and Z directions Degree of protection IP67 (IEC60529) and IP67G 1 (JIS C 0920 Annex 1), IP69K (ISO20653) Indicators Operation indicator (orange), Stability & Communication indicator (green 2) Connection method Pre-wired (standard cable length: 2 m), M8 Connector, M8 Pre-wired Connector (standard cable length: 0.3m), M12 Pre-wired Smartclick Connector (standard cable length: 0.3m) Weight (packed state/ Sensor only) Materials Pre-wired (2 m) Approx. 135 g/approx. 90 g M8 Connector Approx. 75 g/approx. 30 g M8 Pre-wired Connector (0.3 m) Approx. 85 g/approx. 40 g M12 Pre-wired Approx. 95 g/approx. 50 g Smartclick Connector (0.3m) Case Stainless steel (SUS316L) Lens Methacrylate resin (PMMA) Display Polyamide 11 (PA11) Main IO-Link functions IO-Link specification IO-Link Baud rate Communication Data length specifications Minimum cycle time Accessories Operation mode switching between NO and NC, execution of teaching (2-point teaching, Background teaching), setup of the threshold, timer function of the control output and timer time selecting, Restore Factory Settings, Key Lock (Unlock, Lock, Lock (No Button)) Ver. 1.1 COM2 (38.4 kbps), COM3 (230.4 kbps) PD size: 1 byte, OD size: 1 byte (M-sequence type: TYPE_2_1) COM2: 3.5 ms, COM3: 1.2 ms Instruction manual, compliance sheet and index list (attached for IO-Link type only), Note: Mounting Brackets must be ordered separately. 1. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards). The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil. 2. IO-Link Communication mode: blinking 4 E3AS-L Series Engineering Data (Reference Value) 15 Set distance: 200 mm Sensing object: White paper, 100 x 100 mm Y 10 E3AS-L80 Operating Range Y (mm) Operating Range Y (mm) Operating Range E3AS-L200 X 5 0 2 1.5 1 0.5 Y X 0 Set distance: 80 mm Sensing object: White paper, 100 x 100 mm -0.5 -5 -1 -10 -15 -1.5 0 50 100 150 200 -2 0 250 10 20 30 40 50 35 30 25 20 70 80 90 E3AS-L80 Spot diameter (mm) Spot diameter (mm) Spot Diameter vs. Sensing Distance E3AS-L200 60 Distance X (mm) Distance X (mm) 6 5 4 3 15 2 10 1 5 0 50 100 150 200 250 300 350 0 20 40 60 80 Distance X (mm) 200 180 182 mm 182 mm 160 140 120 80 40 Set distance: 80 mm 70 70 mm 71 mm 60 50 30 Set distance: 40 mm 35 mm Set distance: 20 mm 20 35 mm 15.5 mm 15.5 mm 10 20 0 80 40 100 60 120 E3AS-L80 Set distance: 200 mm Sensing distance (mm) Sensing distance (mm) Close-range Characteristics E3AS-L200 100 Distance X (mm) 2 mm 0 mm 0 mm 1 mm 0 White paper Black paper White paper Black paper 1.5 mm 4 mm 1 mm 4 mm White paper Black paper White paper Black paper Material Material 10 Differential distance (%) Differential distance (%) Differential distance for each sensing object Vs. Distance E3AS-L200 E3AS-L80 Reflectance of sensing object/ Reflectance of background 1. 10% (Black paper)/ 90% (White paper) 2. 18% (Gray paper)/ 90% (White paper) 3. 90% (White paper)/ 90% (White paper) 8 6 2 5 Reflectance of sensing object/ Reflectance of background 1. 10% (Black paper)/ 90% (White paper) 2. 18% (Gray paper)/ 90% (White paper) 3. 90% (White paper)/ 90% (White paper) 4 3 2 1 2 4 3 1 2 1 3 0 50 100 150 200 250 Set distance (mm) 0 20 40 60 80 100 Set distance (mm) 5 E3AS-L Series Sensing Object Angle Characteristics Horizontal 5 Set distance: 200 mm Sensing object: White paper/ Black paper 100×100 mm White paper 0 -5 Black paper -10 Vertical Inclination Change in sensing distance (%) Change in sensing distance (%) E3AS-L200 Vertical 5 Set distance: 200 mm Sensing object: White paper/ Black paper 100×100 mm White paper 0 -5 Black paper Horizontal Inclination -10 Angle Angle -15 +θ -15 +θ -θ -θ Sensing object Center line Sensing object Center line -20 -50 -40 -30 -20 -10 0 10 20 30 -20 -50 40 50 -40 -30 -20 -10 0 10 20 Angle θ (°) Horizontal 10 5 Set distance: 80 mm Sensing object: White paper/ Black paper 100×100 mm White paper Black paper 0 -5 Vertical Inclination -10 5 Set distance: 80 mm Sensing object: White paper/ Black paper 100×100 mm White paper 0 Black paper -5 Horizontal Inclination -10 Angle Angle -θ -θ Sensing object Center line Sensing object Center line -40 -30 -20 -10 +θ -15 +θ -15 -20 -50 40 50 Angle θ (°) Change in sensing distance (%) Change in sensing distance (%) E3AS-L80 Vertical 30 0 10 20 30 -20 -50 40 50 -40 -30 -20 -10 0 10 20 30 40 50 Angle θ (°) Angle θ (°) Sensing Distance vs. Sensing Object Material Sensing distance (mm) Sensing distance (mm) E3AS-L200 E3AS-L80 (Set Distance of 200 mm using White Paper) (Set Distance of 80 mm using White Paper) 200 180 160 140 120 80 70 60 50 40 100 80 30 60 20 40 10 20 Mirror SUS Black rubber Black paper Cardboard Veneer Mirror SUS Black rubber Black paper Cardboard Veneer White paper 6 Material White paper 0 0 Material E3AS-L Series I/O Circuit Diagrams/ Timing Charts NPN Output Model Timing chart Output circuit Brown +V OUT1 OUT2 Threshold Stable NEAR E3AS-L□N Stability&Communication indicator (green) 1 ON OFF Operation indicator (orange) ON OFF Control output 1 ON OFF Control output 2 2 ON OFF 0V Stable FAR Black Load 100mA Load 100mA max. max. White 10 to 30 VDC Blue Connector Pin Arrangement M12 Pre-wired Smartclick Connector M8 Connector, M8 Pre-wired Connector 1. Turns off when there is insufficient margin for incident light. In that case, place the workpiece closer to ensure sufficient receiving light intensity. 2. The initial value of control output 2 is reverse of control output 1. PNP Output Model Output circuit IO-Link Communication mode (COM mode) 2 Standard I/O mode (SIO mode) 1 +V OUT1 OUT2 0V E3AS-L□D E3AS-L□T Brown +V 10 to 30 VDC Black C/Q White Load Blue 100mA max. Load DO 100mA max. 0V Connector Pin Arrangement M12 Pre-wired Smartclick Connector Brown +V Black C/Q White IO-Link Master Unit DI/DO Blue 0V Connector Pin Arrangement M8 Connector, M8 Pre-wired Connector M12 Pre-wired Smartclick Connector M8 Connector, M8 Pre-wired Connector 1. Standard I/O mode is used as PNP ON/OFF output. 2. IO-Link Communication mode is used for communications with the IO-Link Master. C/Q performs IO-Link communications. Sensor output DO performs ON/OFF output. Timing charts Output mode Threshold Stable NEAR Stability&Communication indicator (green) 1 Standard I/O mode (SIO mode) ON OFF ON OFF ON OFF ON OFF Operation indicator (orange) Control output 1 3 Control output 2 2 IO-Link Communication mode (COM mode) Stability& Communication indicator (green) Control output 2 2 ON delay Sensing object Flashing (1 second cycle) Operation indicator (orange) Communication output Stable FAR 1. Turns off when there is insufficient margin for incident light. In that case, place the workpiece closer to ensure sufficient receiving light intensity. 2. The initial value of control output 2 is reverse of control output 1. 3. The timer function of the control output 2 can be set up by the IO-Link communications. (It is able to select ON delay, OFF delay, or one-shot function and select a timer time of 1 to 9,999 ms (T).) ON OFF 1 0 ON OFF Present Not present ON OFF ON NC OFF NO 1 0 1 0 OFF delay Sensing object T ON OFF ON NC OFF NO T 1 0 1 0 One Shot Sensing object Present Not present T ON OFF ON NC OFF NO T Present Not present 1 0 1 0 T T Please contact your Omron sales representative regarding the IOLink setup file (IODD file). Note: Shown above are the factory settings. Refer to the index list for the default settings at time of shipment from factory. PNP/COM output logic can be reversed by IO-Link communication. The operation indicator (orange) lights up when control output 1 is ON or communication output is 1. Nomenclature E3AS-L200 E3AS-L80 Operation indicator (orange) Stability&Communication indicator (green) Teach button Note: The indicators work differently depending on sensor status. 7 E3AS-L Series Safety Precautions Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/. Warning Indications Warning level Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. WARNING Caution level Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. CAUTION Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Meaning of Product Safety Symbols General prohibition Indicates the instructions of unspecified prohibited action Caution, fire Indicates the possibility of fires under specific conditions General Caution Indicates unspecified general alert Caution, explosion Indicates the possibility of explosion under specific conditions WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purpose. Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. CAUTION Its component may be damaged and/or degree of protection may be degraded. Please do not apply high pressure water intensively at one place during cleaning. Never use the product with an AC power supply. Otherwise, explosion may result. 8 Precautions for Safe Use The following precautions must be observed to ensure safe operation. (1) Do not reverse the power supply connection or connect to an AC current. (2) Do not short the load. (3) Be sure that before making supply the supply voltage is less than the maximum rated supply voltage (30 VDC). (4) Do not use the product in environments subject to flammable or explosive gases. (5) Do not use the product under a chemical or an oil environment without prior evaluation. (6) Do not attempt to modify the product. Precautions for Correct Use (1) Do not hit the product using a hammer for installation. (2) The product must be installed with the specified torque or less. For M8 connector, the proper tightening torque is from 0.3 to 0.4 Nm. For M12 connector, the proper tightening torque is from 0.39 to 0.49 Nm. In case of M12 smartclick connector, manually tighten the connector. (3) Do not use the product in any atmosphere or environment that exceeds the ratings. (4) Output pulses may occur when the power supply is turned OFF. We recommend that you turn OFF the power supply to the load or load line first. (5) Use an extension cable less than 100 m long for Standard I/O mode and less than 20 m for IO-Link Communication mode. (6) Do not pull on the cable with excessive strength. (7) Please wait for at least 100 ms after turning on the product's power until it is available for use. (8) Though this is type IP67, do not use in the water, rain or outdoors. (9) If the Sensor wiring is placed in the same conduits or ducts as high-voltage or high-power lines, inductive noise may cause malfunction or damage. Wire the cables separately or use a shielded cable. (10) Do not use the product in locations subject to direct sunlight. (11) Do not use the product where humidity is high and dew condensation may occur. (12) Do not use the product where corrosive gases may exist. (13) If high-pressure washing water and so on hits the teach button, it might lead to malfunctioning. So, consider use of the key lock function. (14) Do not apply high-pressure washing water directly to the sensor's light emitting / receiving surface from a short distance. As the antifouling feature may be impaired, keep a sufficient distance from the light emitting / receiving surface. (15) Do not use the product at a location subject to shock or vibration. (16) To use a commercially available switching regulator, FG (frame ground) must be grounded. (17) Do not use organic solvents (e.g. paint thinner and alcohol) for cleaning. Otherwise optical properties and protective structure may deteriorate. (18) Be sure to check the influence caused by surrounding environments such as background objects and LED lighting before using the product. (19) Please dispose in accordance with applicable regulations. E3AS-L Series Dimensions (Unit: mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors Pre-wired Models/Pre-wired Connector Models E3AS-L200□ (-M1TJ/-M3J) E3AS-L80□ (-M1TJ/-M3J) M12 Pre-wired Smartclick Connector type E3AS-L200 -M1TJ/E3AS-L80 -M1TJ □ 14 □ 7.6 4.25 dia. vinyl-insulated round cable with 4 conductors. 2 Operation indicator (orange) Stability&Communication indicator (green) M12×P1 Teach button □ 4.6 Receiver lens (12.1) 9.8 39.3 3 4 M8 Pre-wired connector type E3AS-L200 -M3J/E3AS-L80 -M3J 3 1.5 37.9 23.4 22 Two, M3 11.4 1 □ 4.25 dia. vinyl-insulated round cable with 4 conductors. 2 4 25.4 M8×P1 1 3 Emitter lens 7.9 Minimum bending radius/unbendable length of cord 4.25 dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm), Standard length: 2 m 5.1 Unbendable length 5 mm Minimum bending radius R13 mm Connector Models E3AS-L200□ M3 E3AS-L80□ M3 14 7.6 Operation indicator (orange) Stability&Communication indicator (green) Teach button 22 Two, M3 11.4 1.5 (12.1) 37.9 Receiver lens 9.8 3 4.6 25.4 Emitter lens 7.9 M8×P1 5.1 9.6 9 E3AS-L Series Accessories (Sold Separately) Mounting Brackets E39-L201 Photoelectric Sensor Accessory are installed (Example of E3AS-L200 ) 3 22 □ 11.4 (Four, R1.8) 22.4 16 4 3.5 3.5 6.8 8.5 9 31 8.3 * 14.5 Emitting center 48 17.4 25.4 41.4 R25.4 24.1 16 8.1 16 T3 27 Material: Stainless steel (SUS304) * Accessories 2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W) E39-L202 Photoelectric Sensor Accessory are installed (Example of E3AS-L200 ) □ 11.9 15 5.9 26.7 16.9 13.3 6.7 Four, 3.5 dia. 7 * Emitting center 46 45° 45° 17.4 25.4 25.4 9.4 76 8.1 45° 45° 38.4 30.3 33 33 18 T3 18 14° (Two, R1.8) 8.5 3.5 7 3.5 15.7 R12 18.7 Material: Stainless steel (SUS304) * Accessories 2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W) E39-L203 Photoelectric Sensor Accessory are installed (Example of E3AS-L200 ) □ 22 T3 13.5 3.5 dia. 6.7 6 Emitting center 31.9 3.5 (Two, R1.8) Two, 3.5 20° 44 Material: Stainless steel (SUS304) * Accessories 2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W) 10 32.9 17.4 R25.4 6 (Four, R1.8) 19.85 6.4 * 7 28.6 42 38.2 32.8 8.1 R25.4 E3AS-L Series E39-L204 Photoelectric Sensor Accessory are installed (Example of E3AS-L200 ) 50° 2-3.5 □ (Four, R1.8) 55 dia. 41.5 dia. 14.3 28.5 (28.5) 22.1 12.7 6 6.4 * 1 6.6 21.9 50.2 Two, 3.5 Two, R25.4 45.2 17.4 8.1 Emitting center 23.8 15.7 R25.4 T3 Two, 5 dia. Material: Stainless steel (SUS304) * Accessories 2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W) E39-L211 Photoelectric Sensor Accessory are installed (Example of E3AS-L200 ) 3 □ (Four, R1.8) 11.4 22.4 16 4 22 3.5 3.5 6.8 8.3 8.5 9 31 14.5 6.4 * Emitting center 17.4 25.4 8.1 69.7 R25.4 37.5 45.6 37.5 T3 27 Material: Stainless steel (SUS304) * Accessories 2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W) 11 E3AS-L Series E39-L212 Photoelectric Sensor Accessory are installed (Example of E3AS-L200 ) □ 11.9 5.9 15 26.7 13.9 13.3 6.7 7 * Four, 3.5 dia Emitting center 17.4 25.4 10.3 25.4 8.1 71.6 97.6 60 52 8.5 T3 (Two, R1.8) 3.5 3.5 7 R12 16.6 19.6 Material: Stainless steel (SUS304) * Accessories 2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W) E39-L214 Photoelectric Sensor Accessory are installed (Example of E3AS-L200 ) 50° 2-3.5 □ (Four, R1.8) 55 dia. 41.5 dia. 14.2 28.5 22.1 12.7 6 6.4 6.6 Two, R25.4 * 1 (Four, R1.8) 21.9 17.4 Two, 3.5 8.1 72.6 67.6 9 38.4 45° 30.4 16.7 T3 Two, 5° Material: Stainless steel (SUS304) * Accessories 2-M3-L12 Cross Recessed Pan Head Screws (Attached to SW+JIS W) 12 38.6 Emitting center R25.4 46.5 OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS DE MEXICO • HEAD OFFICE Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com OMRON ARGENTINA • SALES OFFICE Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron. com OTHER OMRON LATIN AMERICA SALES +54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime E588BI-E3-02 Note: Specifications are subject to change. © 2019 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A.
E3AS-L200MN 2M 价格&库存

很抱歉,暂时无法提供与“E3AS-L200MN 2M”相匹配的价格&库存,您可以联系我们找货

免费人工找货